Background Coronary artery disease is the major cause of late cardiac allograft failure. However, few data exist regarding the natural history of changes in intimal and external elastic membrane (EEM) areas after heart transplantation.
Methods and Results In 38 transplant recipients, serial intravascular ultrasound examinations were performed 3.7±2.2 weeks after transplantation and annually thereafter for 5 years. In 59 coronary arteries, we compared 135 matched segments among serial studies. In each segment, intravascular ultrasound images were digitized at 1-mm intervals, and mean values of EEM and lumen and intimal areas were analyzed. In the first year after transplantation, the intimal area increased significantly from 1.8±1.6 to 3.0±2.1 mm2 (P<0.001). Subsequently, the annual increase in intimal area decreased. EEM area did not change during the first year; however, between years 1 and 3, significant expansion of EEM area occurred (15.4±4.6 to 17.2±5.4 mm2, P<0.001). Thereafter, EEM area decreased significantly from 17.2±5.4 mm2 (year 3) to 15.1±4.9 mm2 (year 5, P=0.01). Different mechanisms of lumen loss were observed during 2 phases after transplantation: early lumen loss primarily caused by intimal thickening and late lumen loss caused by EEM area constriction.
Conclusions This serial ultrasound study revealed that most of the intimal thickening occurred during the first year after heart transplantation. Changes in the EEM area showed a biphasic response, consisting of early expansion and late constriction. Thus, different mechanisms of lumen loss were observed during the early and late phases after transplantation.
Key Words: transplantation ultrasonics cardiovascular diseases
This article has been cited by other articles:
![]() |
M. Zakliczynski, J. Nozynski, D. Konecka-Mrowka, A. Krynicka-Mazurek, M. Swierad, M. Maruszewski, R. Przybylski, and M. Zembala Vascular abnormalities and cardiomyocyte lipofuscin deposits in endomyocardial biopsy specimens of heart transplant recipients: Are they related to the development of cardiac allograft vasculopathy? J. Thorac. Cardiovasc. Surg., July 1, 2009; 138(1): 215 - 221. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Bastarrika, C. N. De Cecco, M. Arraiza, S. Mastrobuoni, J. C. Pueyo, M. Ubilla, and G. Rabago Dual-Source CT for Visualization of the Coronary Arteries in Heart Transplant Patients with High Heart Rates Am. J. Roentgenol., August 1, 2008; 191(2): 448 - 454. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Raichlin, J.-H. Bae, Z. Khalpey, B. S. Edwards, W. K. Kremers, A. L. Clavell, R. J. Rodeheffer, R. P. Frantz, C. Rihal, A. Lerman, et al. Conversion to Sirolimus as Primary Immunosuppression Attenuates the Progression of Allograft Vasculopathy After Cardiac Transplantation Circulation, December 4, 2007; 116(23): 2726 - 2733. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-B. Michel, O. Thaunat, X. Houard, O. Meilhac, G. Caligiuri, and A. Nicoletti Topological Determinants and Consequences of Adventitial Responses to Arterial Wall Injury Arterioscler Thromb Vasc Biol, June 1, 2007; 27(6): 1259 - 1268. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Tellides and J. S. Pober Interferon-{gamma} Axis in Graft Arteriosclerosis Circ. Res., March 16, 2007; 100(5): 622 - 632. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Jonas, J. C. Fang, J. C. Wang, S. Giri, D. Elian, Y. Har-Zahav, H. Ly, P. A. Seifert, J. J. Popma, and C. Rogers In-Stent Restenosis and Remote Coronary Lesion Progression Are Coupled in Cardiac Transplant Vasculopathy But Not in Native Coronary Artery Disease J. Am. Coll. Cardiol., August 1, 2006; 48(3): 453 - 461. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Li, K. Tanaka, B. Oeser, J. A. Kobashigawa, and J. M. Tobis Vascular remodelling after cardiac transplantation: a 3-year serial intravascular ultrasound study Eur. Heart J., July 2, 2006; 27(14): 1671 - 1677. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Ramasubbu, P. Schoenhagen, M. A. Balghith, J. Brechtken, K. M. Ziada, S. R. Kapadia, R. E. Hobbs, G. Rincon, S. E. Nissen, and E. M. Tuzcu Repeated intravascular ultrasound imaging in cardiac transplant recipients does not accelerate transplant coronary artery disease J. Am. Coll. Cardiol., May 21, 2003; 41(10): 1739 - 1743. [Abstract] [Full Text] [PDF] |
||||
|
Circulation Home | Subscriptions | Archives | Feedback | Authors | Help | AHA Journals Home | Search Copyright © 2001 American Heart Association, Inc. All rights reserved. Unauthorized use prohibited. |