Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1990;82:1467-1475

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Baumgartner, H.
Right arrow Articles by Maurer, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Baumgartner, H.
Right arrow Articles by Maurer, G.

Circulation, Vol 82, 1467-1475, Copyright © 1990 by American Heart Association


ARTICLES

Discrepancies between Doppler and catheter gradients in aortic prosthetic valves in vitro. A manifestation of localized gradients and pressure recovery

H Baumgartner, S Khan, M DeRobertis, L Czer and G Maurer
Division of Cardiology and Cardiovascular Surgery, Cedars-Sinai Medical Center, Los Angeles, CA 90048.

To evaluate possible causes of discrepancy between Doppler and catheter gradients across prosthetic valves, five sizes (19-27 mm) of St. Jude and Hancock valves were studied in an aortic pulsatile flow model. Catheter gradients at multiple sites distal to the valve were compared with simultaneously obtained Doppler gradients. In the St. Jude valve, significant differences between Doppler and catheter gradients measured 30 mm downstream from the valve were found: Doppler gradients exceeded peak catheter gradients of 10 mm Hg or more by 81 +/- 35% (15 +/- 3.6 mm Hg), and mean catheter gradients by 71 +/- 11% (10.3 +/- 2.5 mm Hg). When the catheter was pulled back through the tunnel-like central orifice of the valve, high localized gradients at the valve plane and significant early pressure recovery were found. When the catheter was pulled back through the large side orifices, gradients at the same level were only 46 +/- 6% of the central orifice gradients (mean difference, 7.6 +/- 4.5 mm Hg). Doppler peak and mean gradients showed excellent agreement with the highest central orifice catheter gradients (mean difference, 1.0 +/- 3.1 and 0.9 +/- 1.5 mm Hg, respectively). A significantly better agreement between Doppler and catheter gradients at 30 mm was found for the Hancock valve, although Doppler peak and mean gradients were still slightly greater than catheter gradients. Doppler gradients exceeded catheter gradients by 18 +/- 10% (3.4 +/- 1.9 mm Hg) and 13 +/- 11% (2.1 +/- 0.9 mm Hg), respectively. When the catheter was pulled back through the valve, the highest gradients were found approximately 20 mm distal to the valve ring.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
CirculationHome page
P. Pibarot and J. G. Dumesnil
Prosthetic Heart Valves: Selection of the Optimal Prosthesis and Long-Term Management
Circulation, February 24, 2009; 119(7): 1034 - 1048.
[Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. Guenzinger, W. B. Eichinger, I. Hettich, S. Bleiziffer, D. Ruzicka, R. Bauernschmitt, and R. Lange
A prospective randomized comparison of the Medtronic Advantage Supra and St Jude Medical Regent mechanical heart valves in the aortic position: is there an additional benefit of supra-annular valve positioning?
J. Thorac. Cardiovasc. Surg., August 1, 2008; 136(2): 462 - 471.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
M. Enriquez-Sarano, V. T. Nkomo, and H. Michelena
Principles and Practice of Echocardiography in Cardiac Surgery
Card. Surg. Adult, January 1, 2008; 3(2008): 315 - 348.
[Full Text]


Home page
Eur. J. Cardiothorac. Surg.Home page
N. J. Howell, B. E. Keogh, V. Barnet, R. S. Bonser, T. R. Graham, S. J. Rooney, I. C. Wilson, and D. Pagano
Patient-prosthesis mismatch does not affect survival following aortic valve replacement.
Eur. J. Cardiothorac. Surg., July 1, 2006; 30(1): 10 - 14.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
W. M. Popescu, E. Prokop, J. A. Elefteriades, K. Kett, and P. G. Barash
Phantom Aortic Valve Pressure Gradient: Discrepancies Between Cardiac Catheterization and Doppler Echocardiography
Anesth. Analg., May 1, 2005; 100(5): 1259 - 1262.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
K. E. Richards, D. Deserranno, E. Donal, N. L. Greenberg, J. D. Thomas, and M. J. Garcia
Influence of structural geometry on the severity of bicuspid aortic stenosis
Am J Physiol Heart Circ Physiol, September 1, 2004; 287(3): H1410 - H1416.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. M. Albes, M. Hartrumpf, V. Rudolph, T. Krempl, E. Huttemann, R. Vollandt, and T. Wahlers
Are mechanical valves with enhanced inner diameter advantageous in the small sized aortic annulus?
Ann. Thorac. Surg., November 1, 2003; 76(5): 1564 - 1570.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. A. Vannan and K. Sarkar
Assessment of mechanical aortic valve prosthesis by means of Doppler echocardiography: what to measure and why?
J. Thorac. Cardiovasc. Surg., August 1, 2003; 126(2): 317 - 320.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
R. A. Levine and E. Schwammenthal
Stenosis is in the eye of the observer: impact of pressure recovery on assessing aortic valve area
J. Am. Coll. Cardiol., February 5, 2003; 41(3): 443 - 445.
[Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
O. Bech-Hanssen, K. Caidahl, I. Wallentin, P. Ask, and B. Wranne
Assessment of effective orifice area of prosthetic aortic valves with Doppler echocardiography: An in vivo and in vitro study
J. Thorac. Cardiovasc. Surg., August 1, 2001; 122(2): 287 - 295.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. E. Girard, F. A. Miller Jr., T. A. Orszulak, C. J. Mullany, S. Montgomery, W. D. Edwards, H. D. Tazelaar, J. F. Malouf, and A. J. Tajik
Reoperation for prosthetic aortic valve obstruction in the era of echocardiography: trends in diagnostic testing and comparison with surgical findings
J. Am. Coll. Cardiol., February 1, 2001; 37(2): 579 - 584.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. Pibarot and J. G. Dumesnil
Hemodynamic and clinical impact of prosthesis-patient mismatch in the aortic valve position and its prevention
J. Am. Coll. Cardiol., October 1, 2000; 36(4): 1131 - 1141.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
P. Becassis, M. Hayot, J.-M. Frapier, F. Leclercq, L. Beck, J.e. Brunet, E. Arnaud, C. Prefaut, P.-A. Chaptal, J. M. Davy, et al.
Postoperative exercise tolerance after aortic valve replacement by small-size prosthesis: Functional consequence of small-size aortic prosthesis
J. Am. Coll. Cardiol., September 1, 2000; 36(3): 871 - 877.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. Garcia, P. Pibarot, J. G. Dumesnil, F. Sakr, and L.-G. Durand
Assessment of Aortic Valve Stenosis Severity : A New Index Based on the Energy Loss Concept
Circulation, February 22, 2000; 101(7): 765 - 771.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
O. Bech-Hanssen, K. Caidahl, B. Wall, P. Myken, S. Larsson, and I. Wallentin
INFLUENCE OF AORTIC VALVE REPLACEMENT, PROSTHESIS TYPE, AND SIZEON FUNCTIONAL OUTCOME AND VENTRICULAR MASS IN PATIENTS WITH AORTIC STENOSIS
J. Thorac. Cardiovasc. Surg., July 1, 1999; 118(1): 57 - 65.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
H. Baumgartner, T. Stefenelli, J. Niederberger, H. Schima, and G. Maurer
"overestimation" of catheter gradients by doppler ultrasound in patients with aortic stenosis: a predictable manifestation of pressure recovery
J. Am. Coll. Cardiol., May 1, 1999; 33(6): 1655 - 1661.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. Y. Leung, J. Wong, L. Rodriguez, M. Pu, P. M. Vandervoort, and J. D. Thomas
Application of Color Doppler Flow Mapping to Calculate Orifice Area of St Jude Mitral Valve
Circulation, September 22, 1998; 98(12): 1205 - 1211.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
R. H. Marcus, R. S. Heinrich, J. Bednarz, S. Lupovitch, J. Abruzzo, R. Borok, B. Vandenberg, R. E. Kerber, W. Piccione, A. P. Yoganathan, et al.
Assessment of Small-Diameter Aortic Mechanical Prostheses : Physiological Relevance of the Doppler Gradient, Utility of Flow Augmentation, and Limitations of Orifice Area Estimation
Circulation, September 1, 1998; 98(9): 866 - 872.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. Niederberger, H. Schima, G. Maurer, and H. Baumgartner
Importance of Pressure Recovery for the Assessment of Aortic Stenosis by Doppler Ultrasound: Role of Aortic Size, Aortic Valve Area, and Direction of the Stenotic Jet In Vitro
Circulation, October 15, 1996; 94(8): 1934 - 1940.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. R. Gonzalez-Juanatey, J. M. Garca-Acuna, M. V. Fernandez, A. A. Cendon, V. C. Fuentes, J. B. Garcia-Bengoechea, and M. G. de la Pena
INFLUENCE OF THE SIZE OF AORTIC VALVE PROSTHESES ON HEMODYNAMICS AND CHANGE IN LEFT VENTRICULAR MASS: IMPLICATIONS FOR THE SURGICAL MANAGEMENT OF AORTIC STENOSIS
J. Thorac. Cardiovasc. Surg., August 1, 1996; 112(2): 273 - 280.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. B. Izzat, I. Birdi, P. Wilde, A. J. Bryan, and G. D. Angelini
COMPARISON OF HEMODYNAMIC PERFORMANCES OF ST. JUDE MEDICAL AND CARBOMEDICS 21 MM AORTIC PROSTHESES BY MEANS OF DOBUTAMINE STRESS ECHOCARDIOGRAPHY
J. Thorac. Cardiovasc. Surg., February 1, 1996; 111(2): 408 - 415.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
A. Laske, R. Jenni, M. Maloigne, G. Vassalli, O. Bertel, and M. I. Turina
Pressure Gradients Across Bileaflet Aortic Valves by Direct Measurement and Echocardiography
Ann. Thorac. Surg., January 1, 1996; 61(1): 48 - 57.
[Abstract] [Full Text]


Home page
CirculationHome page
P. M. Vandervoort, N. L. Greenberg, M. Pu, K. A. Powell, D. M. Cosgrove, and J. D. Thomas
Pressure Recovery in Bileaflet Heart Valve Prostheses : Localized High Velocities and Gradients in Central and Side Orifices With Implications for Doppler-Catheter Gradient Relation in Aortic and Mitral Position
Circulation, December 15, 1995; 92(12): 3464 - 3472.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
M. B. Izzat, I. Birdi, P. Wilde, A. J. Bryan, and G. D. Angelini
Evaluation of the Hemodynamic Performance of Small CarboMedics Aortic Prostheses Using Dobutamine-Stress Doppler Echocardiography
Ann. Thorac. Surg., October 1, 1995; 60(4): 1048 - 1052.
[Abstract] [Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
S. Khan, A. Chaux, J. Matloff, C. Blanche, M. DeRobertis, R. Kass, T. P. Tsai, A. Trento, S. Nessim, R. Gray, et al.
The St. Jude Medical valveExperience with 1000 cases
J. Thorac. Cardiovasc. Surg., December 1, 1994; 108(6): 1010 - 1020.
[Abstract] [Full Text]