Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1992;86:363-374

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fromer, M.
Right arrow Articles by Camm, A. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fromer, M.
Right arrow Articles by Camm, A. J.

Circulation, Vol 86, 363-374, Copyright © 1992 by American Heart Association


ARTICLES

Efficacy of automatic multimodal device therapy for ventricular tachyarrhythmias as delivered by a new implantable pacing cardioverter- defibrillator. Results of a European multicenter study of 102 implants

M Fromer, J Brachmann, M Block, J Siebels, E Hoffmann, J Almendral, OJ Ohm, K den Dulk, P Coumel and AJ Camm
Division de Cardiologie, CHUV, Lausanne, Switzerland.

BACKGROUND. Third-generation implantable cardioverter-defibrillators are devices designed to treat ventricular tachycardia (VT) and ventricular fibrillation (VF) by means of overdrive pacing, cardioversion, or defibrillation. So far, the efficacy of tiered therapy has been documented only in small series. Therefore, a European multicenter clinical evaluation study of a new tachyarrhythmia control device, the Medtronic PCD pacer-cardioverter-defibrillator with epicardial patch-lead configuration, was undertaken. METHODS AND RESULTS. We report on 102 patients (mean age, 55 +/- 13 years) from 11 European centers. PCD devices implanted between May 1989 and February 1991 were included. The patients suffered from hemodynamically significant ventricular tachyarrhythmias not suppressed by antiarrhythmic drug therapy and unrelated to acute myocardial infarction; one patient had nonsustained VT and severely depressed left ventricular function. Seventy patients had coronary artery disease with old myocardial infarctions, 23 had cardiomyopathies of various etiologies, and nine patients had no detectable heart disease. Mean ejection fraction was 36 +/- 14% (range, 10-76%). Mean intraoperative defibrillation threshold (51 patients) was 10.6 +/- 5.1 J (range, 2-18 J). The documented follow-up ranged from 1 to 21 months (mean, 9.4 +/- 5.8 months), or 79.9 cumulative patient-years. Perioperative mortality was 3.9%. The actuarial survival rate at 12 months was 91%. One sudden arrhythmic death occurred. Sixty patients (58%) received device therapy. Seventeen patients had therapies only for "VF" episodes, 16 patients only for VT, and 28 patients for VT and "VF" episodes. Based on device memory data, 1,235 spontaneous VT episodes were detected and treated in 43 patients. Twelve hundred four of these VT episodes received painless initial antitachycardia pacing therapy, restoring sinus rhythm in 91%. The 108 ongoing episodes received 209 multiple therapeutic attempts. Eighty-five additional overdrive pacing therapies restored sinus rhythm in 30%. Initial ineffective antitachycardia pacing therapies received 51 cardioversion pulses. The success rate was 61%. Seventy-three additional cardioversion pulses were delivered to backup ineffective pacing therapy as well as ineffective secondary cardioversion pulses. Their success rate was only 40%. Two hundred eighty-six spontaneous episodes were detected in 44 patients as "VF." Overall defibrillation efficacy was 97.6%. CONCLUSIONS. The implanted device nearly eliminates sudden arrhythmic death in patients with documented, potentially fatal ventricular tachyarrhythmias. Automatic tiered therapy is highly effective to restore sinus rhythm, provided that an integrated two-zone tachycardia detection algorithm is used, assigning lower tachycardia rates to overdrive pacing and/or cardioversion and higher tachycardia rates to defibrillation. In general, spontaneous VTs can be terminated by automatic overdrive pacing, and painful or disturbing countershock therapies are not required to terminate the majority of spontaneous VT episodes.


This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
Developed in Collaboration With the European Heart, D. P. Zipes, A. J. Camm, M. Borggrefe, A. E. Buxton, B. Chaitman, M. Fromer, G. Gregoratos, G. Klein, A. J. Moss, et al.
ACC/AHA/ESC 2006 Guidelines for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death: A Report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Develop Guidelines for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death)
J. Am. Coll. Cardiol., September 5, 2006; 48(5): e247 - e346.
[Full Text] [PDF]


Home page
EuropaceHome page
Writing Committee Members, D. P. Zipes, A. J. Camm, M. Borggrefe, A. E. Buxton, B. Chaitman, M. Fromer, G. Gregoratos, G. Klein, A. J. Moss, et al.
ACC/AHA/ESC 2006 guidelines for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: A report of the American College of Cardiology/American Heart Association Task Force and the European Society of Cardiology Committee for Practice Guidelines (Writing Committee to Develop Guidelines for Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death) Developed in collaboration with the European Heart Rhythm Association and the Heart Rhythm Society
Europace, September 1, 2006; 8(9): 746 - 837.
[Full Text] [PDF]


Home page
J Am Coll CardiolHome page
L. B. Mitchell, E. A. Pineda, J. L. Titus, P. M. Bartosch, and D. G. Benditt
Sudden death in patients with implantable cardioverter defibrillators: The importance of post-shock electromechanical dissociation
J. Am. Coll. Cardiol., April 17, 2002; 39(8): 1323 - 1328.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. S. Wathen, M. O. Sweeney, P. J. DeGroot, A. J. Stark, J. L. Koehler, M. B. Chisner, C. Machado, and W. O. Adkisson
Shock Reduction Using Antitachycardia Pacing for Spontaneous Rapid Ventricular Tachycardia in Patients With Coronary Artery Disease
Circulation, August 14, 2001; 104(7): 796 - 801.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
N. A. Freedberg, J. N. Hill, R. I. Fogel, E. N. Prystowsky, and the CARE Group
Recurrence of symptomatic ventricular arrhythmias in patients with implantable cardioverter defibrillator after the first device therapy: Implications for antiarrhythmic therapy and driving restrictions
J. Am. Coll. Cardiol., June 1, 2001; 37(7): 1910 - 1915.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. Rosenqvist, T. Beyer, M. Block, K. den Dulk, J. Minten, and F. Lindemans
Adverse Events With Transvenous Implantable Cardioverter-Defibrillators : A Prospective Multicenter Study
Circulation, August 18, 1998; 98(7): 663 - 670.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. Arenal, J. Almendral, J. Villacastin, R. Morris, E. Castellanos, and J. L. Delcan
First Postpacing Interval Variability During Right Ventricular Stimulation : A Single Algorithm for the Differential Diagnosis of Regular Tachycardias
Circulation, August 18, 1998; 98(7): 671 - 677.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. Schaumann, F. v. z. Muhlen, B. Herse, B.-D. Gonska, and H. Kreuzer
Empirical Versus Tested Antitachycardia Pacing in Implantable Cardioverter Defibrillators : A Prospective Study Including 200 Patients
Circulation, January 13, 1998; 97(1): 66 - 74.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. E. Epstein, W. M. Miles, D. G. Benditt, A. J. Camm, E. J. Darling, P. L. Friedman, A. Garson, J. C. Harvey, G. A. Kidwell, G. J. Klein, et al.
Personal and Public Safety Issues Related to Arrhythmias That May Affect Consciousness: Implications for Regulation and Physician Recommendations: A Medical/Scientific Statement From the American Heart Association and the North American Society of Pacing and Electrophysiology
Circulation, September 1, 1996; 94(5): 1147 - 1166.
[Full Text]


Home page
CirculationHome page
J. Villacastin, J. Almendral, A. Arenal, J. Albertos, J. Ormaetxe, R. Peinado, H. Bueno, J. L. Merino, A. Pastor, O. Medina, et al.
Incidence and Clinical Significance of Multiple Consecutive, Appropriate, High-Energy Discharges in Patients With Implanted Cardioverter-Defibrillators
Circulation, February 15, 1996; 93(4): 753 - 762.
[Abstract] [Full Text]


Home page
CirculationHome page
G. K. Jones, J. E. Poole, P. J. Kudenchuk, G. L. Dolack, G. Johnson, P. DeGroot, M. J. Gleva, M. Raitt, and G. H. Bardy
A Prospective Randomized Evaluation of Implantable Cardioverter-Defibrillator Size on Unipolar Defibrillation System Efficacy
Circulation, November 15, 1995; 92(10): 2940 - 2943.
[Abstract] [Full Text]


Home page
CirculationHome page
S. L. Pinski and G. J. Fahy
The Proarrhythmic Potential of Implantable Cardioverter-Defibrillators
Circulation, September 15, 1995; 92(6): 1651 - 1664.
[Abstract] [Full Text]


Home page
CirculationHome page
D. P. Zipes and D. Roberts
Results of the International Study of the Implantable Pacemaker Cardioverter-Defibrillator : A Comparison of Epicardial and Endocardial Lead Systems
Circulation, July 1, 1995; 92(1): 59 - 65.
[Abstract] [Full Text]


Home page
CirculationHome page
A. M. Gillis, R. S. Sheldon, D. G. Wyse, J. W. Leitch, R. Yee, G. J. Klein, H. J. Duff, and L. B. Mitchell
Long-term Reproducibility of Ventricular Tachycardia Induction in Patients With Implantable Cardioverter/Defibrillators : Serial Noninvasive Studies
Circulation, May 15, 1995; 91(10): 2605 - 2613.
[Abstract] [Full Text]


Home page
CirculationHome page
S. O. Nunain, M. Roelke, T. Trouton, S. Osswald, Y. H. Kim, G. Sosa-Suarez, D. R. Brooks, B. McGovern, M. Guy, D. F. Torchiana, et al.
Limitations and Late Complications of Third-Generation Automatic Cardioverter-Defibrillators
Circulation, April 15, 1995; 91(8): 2204 - 2213.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
J. M. Piehler, D. A. Killen, A. M. Borkon, W. A. Reed, M. E. Gorton, G. M. Gura Jr, and A. H. Kragel
Right Atrial Compression Related to Defibrillator Patches
Ann. Thorac. Surg., March 1, 1995; 59(3): 684 - 688.
[Abstract] [Full Text]


Home page
CirculationHome page
E. U. Alt, P. C. Fotuhi, R. L. Callihan, D. L. Rollins, E. Mestre, M. P. Combs, W. M. Smith, and R. E. Ideker
Improved Defibrillation Threshold With a New Epicardial Carbon Electrode Compared With a Standard Epicardial Titanium Patch
Circulation, January 15, 1995; 91(2): 445 - 450.
[Abstract] [Full Text]