Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1995;92:1291-1299

This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Malkin, R. A.
Right arrow Articles by Ideker, R. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Malkin, R. A.
Right arrow Articles by Ideker, R. E.

(Circulation. 1995;92:1291-1299.)
© 1995 American Heart Association, Inc.


Articles

Effect of Rapid Pacing and T-Wave Scanning on the Relation Between the Defibrillation and Upper-Limit-of-Vulnerability Dose-Response Curves

Robert A. Malkin, PhD; Salim F. Idriss, BSE; Robert G. Walker, BS; Raymond E. Ideker, MD, PHD

From the Duke-North Carolina NSF/ERC in Emerging Cardiovascular Technologies, Department of Electrical Engineering, Duke University, and Departments of Pathology and Medicine, Duke University Medical Center, Durham, NC.

Correspondence to Robert A. Malkin, The University of Memphis, Herff College of Engineering, Biomedical Engineering Department, Memphis, TN 38152.

Background The critical-point and upper-limit-of-vulnerability (ULV) hypotheses predict that the ULV dose-response curve should be steeper and to the right of the defibrillation (DF) curve. Yet, some recent experimental data contradict this prediction. Two studies are presented that test two explanations for the contradiction: (1) Testing at a single point in the T wave underestimates the ULV dose-response curve and (2) ULV testing at normal heart rates does not mimic the mechanical or electrical state of the heart in ventricular fibrillation (VF).

Methods and Results A nonthoracotomy lead system with a biphasic waveform was used throughout. In eight dogs, the dose-response curve widths (a measure of steepness) were compared between DF data and ULV data gathered at the peak (ULVPK), middownslope (ULVDWN), midupslope (ULVUP), and all times (scanning or ULVSCN) in the T wave. In another eight dogs, ULV data (ULVRAP) were gathered by scanning the T wave after 15 rapidly paced beats (166- to 198-ms pacing interval). The rapid pacing interval was chosen to more closely mimic the hemodynamics and activation rate of early VF. ULV data (ULVSTD) at normal heart rates were gathered for all animals. In the first study, scanning significantly reduced the ULV curve width (ULVSCN, 63.5±29.7 V; ULVPK, 81.9±45.2 V; ULVDWN, 116±36.5 V; DF, 105±22.0 V; P<.03) and significantly shifted the ULV curve to the right (ULV80 SCN, 410±62.6 V; ULV80 PK, 266±35.3 V; ULV80 DWN, 355±80.4 V; DF80, 427±60.9 V; P<.001). The subscript 80 signifies that the subject was left in normal sinus rhythm 80% of the time after that stimulus strength was delivered. In the second study, the ULVRAP curve was shifted dramatically to the right, the average ULV50 RAP being greater than the average DF90. Furthermore, 92% of the ULVRAP VF inductions occurred between 10 ms before and 50 ms after the peak of the T wave, suggesting that scanning of the entire T wave may not be necessary.

Conclusions With a single rapidly paced ULV sequence with limited T-wave scanning, it may be possible to estimate highly effective defibrillation doses with few VF episodes and high-voltage stimuli.


Key Words: defibrillation • electric stimulation • fibrillation • death, sudden




This article has been cited by other articles:


Home page
Circ. Res.Home page
B. Rodriguez, L. Li, J. C. Eason, I. R. Efimov, and N. A. Trayanova
Differences Between Left and Right Ventricular Chamber Geometry Affect Cardiac Vulnerability to Electric Shocks
Circ. Res., July 22, 2005; 97(2): 168 - 175.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
B. Rodriguez, B. M. Tice, J. C. Eason, F. Aguel, J. M. Ferrero Jr., and N. Trayanova
Effect of acute global ischemia on the upper limit of vulnerability: a simulation study
Am J Physiol Heart Circ Physiol, June 1, 2004; 286(6): H2078 - H2088.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
M. S. Link, B. J. Maron, P. J. Wang, B. A. VanderBrink, W. Zhu, and N. A. M. Estes III
Upper and lower limits of vulnerability to sudden arrhythmic death with chest-wall impact (commotio cordis)
J. Am. Coll. Cardiol., January 1, 2003; 41(1): 99 - 104.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Heart Circ. Physiol.Home page
M. Yashima, Y.-H. Kim, S. Armin, T.-J. Wu, Y. Miyauchi, W. J. Mandel, P.-S. Chen, and H. S. Karagueuzian
On the mechanism of the probabilistic nature of ventricular defibrillation threshold
Am J Physiol Heart Circ Physiol, January 1, 2003; 284(1): H249 - H255.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
N. Chattipakorn, P. C. Fotuhi, C. M. Sreenan, J. B. White, and R. E. Ideker
Pacing After Shocks Stronger Than the Upper Limit of Vulnerability : Impact on Fibrillation Induction
Circulation, March 21, 2000; 101(11): 1337 - 1343.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
P. N. Schauerte, K. Ziegert, M. Waldmann, F. A. Schondube, F. Birkenhauer, K. Mischke, M. Grossmann, P. Hanrath, and C. Stellbrink
Effect of Biphasic Shock Duration on Defibrillation Threshold With Different Electrode Configurations and Phase 2 Capacitances : Prediction by Upper-Limit-of-Vulnerability Determination
Circulation, March 23, 1999; 99(11): 1516 - 1522.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. Huang, B. H. KenKnight, G. P. Walcott, D. L. Rollins, W. M. Smith, and R. E. Ideker
Effects of Transvenous Electrode Polarity and Waveform Duration on the Relationship Between Defibrillation Threshold and Upper Limit of Vulnerability
Circulation, August 19, 1997; 96(4): 1351 - 1359.
[Abstract] [Full Text]


Home page
CirculationHome page
C. D. Swerdlow, C. T. Peter, R. M. Kass, E. S. Gang, W. J. Mandel, C. Hwang, D. J. Martin, and P.-S. Chen
Programming of Implantable Cardioverter-Defibrillators on the Basis of the Upper Limit of Vulnerability
Circulation, March 18, 1997; 95(6): 1497 - 1504.
[Abstract] [Full Text]