Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1996;93:1083-1086

This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wittkampf, F. H.M.
Right arrow Articles by Jackman, W. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wittkampf, F. H.M.
Right arrow Articles by Jackman, W. M.

(Circulation. 1996;93:1083-1086.)
© 1996 American Heart Association, Inc.


Articles

Thermal Latency in Radiofrequency Ablation

Fred H.M. Wittkampf, PhD; Hiroshi Nakagawa, MD; William S. Yamanashi, PhD; Shinobu Imai, MD; Warren M. Jackman, MD

From the Heart Lung Institute, Department of Cardiology, University Hospital Utrecht, the Netherlands (F.H.M.W.), and the Cardiovascular Section, Department of Medicine, University of Oklahoma Health Sciences Center and the Department of Veterans Affairs Medical Center, Oklahoma City, Okla.

Correspondence to Fred H.M. Wittkampf, PhD, Heart Lung Institute, Department of Cardiology, University Hospital Utrecht, PO Box 85500, 3508 GA, Utrecht, The Netherlands. E-mail j.a.vangestel@hli.azu.nl.

Background Progression of unintentionally induced atrioventricular delay is occasionally observed directly after termination of radiofrequency delivery in the vicinity of the atrioventricular node. We postulated that the application of a radiofrequency pulse may result in a tissue temperature rise that continues after the pulse.

Methods and Results Using the thigh muscle preparation, 5-, 10-, 20-, and 30-second pulses were applied at 30 to 40 W via a standard 4-mm tip electrode with 10-g contact pressure. Forty-one undisturbed pulses were delivered while recording intramural temperatures at 2-, 4-, and 7-mm depth. Maximal "thermal latency" was observed with the shortest pulse duration and at greatest depth. With 5-second applications, tissue temperature at 7-mm depth peaked 11.6 seconds after termination of radiofrequency delivery and stayed above end-of-pulse value as long as 34.5 seconds after the pulse. The additional rise in tissue temperature was 2.9°C. If only recordings within the lesion border zone were considered, the duration of latency was maximal with 10-second pulses: an additional gain in tissue temperature of 3.4°C was observed 6.4 seconds after the pulse while tissue temperature stayed above end-of-pulse value during 18.3 seconds.

Conclusions With relatively short applications, tissue temperature continues to rise after termination of radiofrequency delivery. This "thermal latency" may result in lesion growth after the pulse and may so explain the incidentally observed progression of conduction block after short pulses in the vicinity of the atrioventricular node. It also may explain the apparent discrepancy between lesion growth rate and intramural temperature rise studies.


Key Words: ablation • conduction • atrioventricular node • catheter




This article has been cited by other articles:


Home page
CirculationHome page
G. K. Bruce, T. J. Bunch, M. A. Milton, A. Sarabanda, S. B. Johnson, and D. L. Packer
Discrepancies Between Catheter Tip and Tissue Temperature in Cooled-Tip Ablation: Relevance to Guiding Left Atrial Ablation
Circulation, August 16, 2005; 112(7): 954 - 960.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
T. J. Bunch, G. K. Bruce, S. B. Johnson, A. Sarabanda, M. A. Milton, and D. L. Packer
Analysis of Catheter-Tip (8-mm) and Actual Tissue Temperatures Achieved During Radiofrequency Ablation at the Orifice of the Pulmonary Vein
Circulation, November 9, 2004; 110(19): 2988 - 2995.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
R. S. Tan, R. Kam Ming Li, and W. S. Teo
Power Versus Temperature-Controlled Ablation of Supraventricular Tachycardia
Asian Cardiovasc Thorac Ann, June 1, 2001; 9(2): 115 - 118.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
A. Erdogan, J. Carlsson, S. Grumbrecht, S. Kostin, B. Schulte, M. Schlapp, J. Neuzner, and H. F. Pitschner
Electrochemical potentials during radiofrequency energy delivery: a new method to control catheter ablation of arrhythmias
Europace, January 1, 2001; 3(3): 201 - 207.
[Abstract] [PDF]


Home page
CirculationHome page
H. Nakagawa, F. H. M. Wittkampf, W. S. Yamanashi, J. V. Pitha, S. Imai, B. Campbell, M. Arruda, R. Lazzara, and W. M. Jackman
Inverse Relationship Between Electrode Size and Lesion Size During Radiofrequency Ablation With Active Electrode Cooling
Circulation, August 4, 1998; 98(5): 458 - 465.
[Abstract] [Full Text] [PDF]