Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1996;94:445-451

This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ismail, S.
Right arrow Articles by Kaul, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ismail, S.
Right arrow Articles by Kaul, S.
Right arrowPubmed/NCBI databases
*Substance via MeSH

(Circulation. 1996;94:445-451.)
© 1996 American Heart Association, Inc.


Articles

Relation Between Air-Filled Albumin Microbubble and Red Blood Cell Rheology in the Human Myocardium

Influence of Echocardiographic Systems and Chest Wall Attenuation

Suad Ismail, MD; Ananda R. Jayaweera, PhD; Gustavo Camarano, MD; Lawrence W. Gimple, MD; Eric R. Powers, MD; Sanjiv Kaul, MD

the Cardiovascular Division, University of Virginia School of Medicine (Charlottesville).

Correspondence to Sanjiv Kaul, MD, Cardiovascular Division, Box 158, Medical Center, University of Virginia, Charlottesville, VA 22908.

Background We have previously shown that the intravascular rheology of sonicated air-filled albumin microbubbles is similar to that of red blood cells (RBCs) and that their myocardial transit rate is also similar to that of RBCs in the beating canine heart. In the present study, we tested the hypothesis that the myocardial transit rates of these microbubbles reflect those of RBCs in humans at different coronary flow rates.

Methods and Results RBC and microbubble transit rates were measured in 17 patients undergoing coronary angiography: in 8, measurements were made only at rest, whereas in 9, they were performed both at rest and during a pacing-induced increase in coronary blood flow. A {gamma}-variate function was used to derive mean RBC and microbubble transit rates from the time-activity and time-intensity plots after the left main injection of RBCs and microbubbles, respectively. There was linear correlation between the myocardial transit rates with both tracers with the slope of the correlation determined by the specific echocardiographic system that was used. Microbubble transit rate consistently overestimated RBC transit rate due to artificial narrowing of the time-intensity curves caused by chest wall attenuation of the echocardiographic signal, which was confirmed through in vitro experiments.

Conclusions There is close correlation between air-filled albumin microbubbles and RBC rheology in the human myocardium. The use of these microbubbles in the cardiac catheterization laboratory could, therefore, provide further insights into myocardial blood flow/myocardial blood volume relations in humans.


Key Words: contrast media • echocardiography • blood flow




This article has been cited by other articles:


Home page
CirculationHome page
K. Wei, M. Ragosta, J. Thorpe, M. Coggins, S. Moos, and S. Kaul
Noninvasive Quantification of Coronary Blood Flow Reserve in Humans Using Myocardial Contrast Echocardiography
Circulation, May 29, 2001; 103(21): 2560 - 2565.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
G. Mychaskiw II, A. E. Badr, R. Tibbs, B. R. Clower, and J. H. Zhang
Optison (FS069) Disrupts the Blood-Brain Barrier in Rats
Anesth. Analg., October 1, 2000; 91(4): 798 - 803.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
T. Yasu, G. W. Schmid-Schonbein, B. Cotter, and A. N. DeMaria
Flow dynamics of QW7437, a new dodecafluoropentane ultrasound contrast agent, in the microcirculation: Microvascular mechanisms for persistent tissue echo enhancement
J. Am. Coll. Cardiol., August 1, 1999; 34(2): 578 - 586.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. Z. Linka, J. Sklenar, K. Wei, A. R. Jayaweera, D. M. Skyba, and S. Kaul
Assessment of Transmural Distribution of Myocardial Perfusion With Contrast Echocardiography
Circulation, November 3, 1998; 98(18): 1912 - 1920.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
K. Wei, A. R. Jayaweera, S. Firoozan, A. Linka, D. M. Skyba, and S. Kaul
Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: bolus or continuous infusion?
J. Am. Coll. Cardiol., July 1, 1998; 32(1): 252 - 260.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
S. Kaul
Myocardial Contrast Echocardiography : 15 Years of Research and Development
Circulation, November 18, 1997; 96(10): 3745 - 3760.
[Full Text]