Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1997;95:449-454

This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hong, M. K.
Right arrow Articles by Leon, M. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hong, M. K.
Right arrow Articles by Leon, M. B.

(Circulation. 1997;95:449-454.)
© 1997 American Heart Association, Inc.


Articles

Continuous Subcutaneous Angiopeptin Treatment Significantly Reduces Neointimal Hyperplasia in a Porcine Coronary In-Stent Restenosis Model

Mun K. Hong, MD; Kenneth M. Kent, MD, PhD; Roxana Mehran, MD; Gary S. Mintz, MD; Fermin O. Tio, MD; Marie Foegh, MD, DSc; S. Chiu Wong, MD; Seedabarum S. Cathapermal, PhD; Martin B. Leon, MD

the Department of Internal Medicine (Cardiology Division) of the Washington (DC) Hospital Center; the Department of Pathology, University of Texas at San Antonio (F.O.T.); and the Department of Surgery, Georgetown University Medical Center, Washington, DC (M.F., S.S.C.).

Background In-stent restenosis results primarily from neointimal hyperplasia. This study evaluated the efficacy and the optimal mode of administration of angiopeptin, a somatostatin analogue with antiproliferative activity, in a porcine coronary in-stent restenosis model.

Methods and Results Forty pigs were randomly assigned to one of four groups (n=10 per group): (1) controls receiving saline infusion at the site of stent implantation via a local delivery catheter, (2) local treatment group receiving one-time treatment (200 µg angiopeptin) at the site of stent placement, (3) systemic treatment group receiving continuous angiopeptin over a 1-week period via a subcutaneous osmotic pump (200 µg/kg total dose), and (4) combined local and systemic treatment group. Then, one oversized Palmaz-Schatz stent (mean ratio of stent to artery diameters, 1.3:1) was implanted in the left anterior descending coronary artery. The degree of neointimal reaction was evaluated 4 weeks later by angiography (maximal percent diameter stenosis), intravascular ultrasound (total in-stent neointimal volume), and histology (maximal area stenosis). Systemic treatment produced the least neointimal hyperplasia and significantly reduced in-stent restenosis compared with the control group by all end points, despite similar degrees of injury. Angiography showed 25±17% versus 50±17% diameter stenosis in the systemic angiopeptin group versus the control group (P<.0001), intravascular ultrasound revealed 23±10 versus 58±27 mm3 neointimal volume in the systemic angiopeptin versus control group (P=.0002), and histology showed 41±16% versus 69±18% area stenosis (P=.0016) in the systemic angiopeptin versus control group. Plasma angiopeptin levels revealed rapid clearance (within 6 hours) after local therapy, whereas the levels persisted for up to 2 weeks in the systemic group.

Conclusions This study shows that continuous subcutaneous treatment with angiopeptin after stent implantation significantly reduces in-stent restenosis by inhibiting neointimal hyperplasia.


Key Words: stents • restenosis • angioplasty




This article has been cited by other articles:


Home page
Eur Heart JHome page
R. Hoffmann and G.S. Mintz
Coronary in-stent restenosis--predictors, treatment and prevention
Eur. Heart J., November 1, 2000; 21(21): 1739 - 1749.
[PDF]


Home page
J Am Coll CardiolHome page
T. Takagi, K. Yoshida, T. Akasaka, S. Kaji, T. Kawamoto, Y. Honda, A. Yamamuro, T. Hozumi, and S. Morioka
Hyperinsulinemia during oral glucose tolerance test is associated with increased neointimal tissue proliferation after coronary stent implantation in nondiabetic patients: A serial intravascular ultrasound study
J. Am. Coll. Cardiol., September 1, 2000; 36(3): 731 - 738.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
J Gunn and D Cumberland
Stent coatings and local drug delivery. State of the art
Eur. Heart J., December 1, 1999; 20(23): 1693 - 1700.
[PDF]