Donate Help Contact The AHA Sign In Home
American Heart Association
Circulation
Search: search_blue_button Advanced Search
Circulation. 1997;96:2693-2700

This Article
Right arrow Full Text
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cooper, R. A. S.
Right arrow Articles by Ideker, R. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cooper, R. A. S.
Right arrow Articles by Ideker, R. E.

(Circulation. 1997;96:2693-2700.)
© 1997 American Heart Association, Inc.


Articles

Internal Cardioversion of Atrial Fibrillation

Marked Reduction in Defibrillation Threshold With Dual Current Pathways

Randolph A. S. Cooper, MD; William M. Smith, PhD; ; Raymond E. Ideker, MD, PhD

From the Department of Medicine, Division of Cardiovascular Diseases, The University of Alabama at Birmingham Medical Center.

Background The ultimate acceptance of a fully automatic atrial defibrillator will depend on the reduction of pain to acceptable levels, requiring a marked decrease in defibrillation thresholds. The purpose of this study was to determine whether atrial defibrillation thresholds can be reduced by sequential shocks delivered through two current pathways.

Methods and Results Sustained atrial fibrillation was induced with rapid atrial pacing in 12 adult sheep. Defibrillation electrodes were positioned in the right atrial appendage (RAap), distal coronary sinus (DCS), proximal coronary sinus (CSos), main/left pulmonary artery junction (PA), and right ventricular apex (RV). Single-capacitor biphasic waveforms (3/1 ms) were delivered through combinations of these electrodes. Probability-of-success curves were determined for single shocks with a single current pathway and sequential shocks with either single- or dual current pathways. The ED50 for delivered energy for the dual current pathway RAap to DCS then CSos to PA was 0.36±0.13 J, which was significantly lower than the ED50 of the standard single current pathway RAap to DCS (1.31±0.3 J) and was significantly lower than all other configurations tested.

Conclusions Internal atrial defibrillation thresholds can be markedly reduced with two sequential biphasic shocks delivered over two current pathways compared with the standard single shock delivered over a single current pathway or with sequential shocks delivered over a single current pathway.


Key Words: atrium • fibrillation • defribillation




This article has been cited by other articles:


Home page
EuropaceHome page
S. J. Walsh, G. Manoharan, O. J. Escalona, J. Santos, N. Evans, J. McC. Anderson, M. Stevenson, J. D. Allen, and A.A. J. Adgey
Novel rectangular biphasic and monophasic waveforms delivered by a radiofrequency-powered defibrillator compared with conventional capacitor-based waveforms in transvenous cardioversion of atrial fibrillation.
Europace, October 1, 2006; 8(10): 873 - 880.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
C. M. Dollery and P. Libby
Atherosclerosis and proteinase activation
Cardiovasc Res, February 15, 2006; 69(3): 625 - 635.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
G. Q. Villani, M. F. Piepoli, and A. Capucci
Reproducibility of internal atrial defibrillation threshold in paroxysmal and persistent atrial fibrillation
Europace, January 1, 2004; 6(4): 267 - 272.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
J.C. Geller, S. Reek, C. Timmermans, T. Kayser, H.-F. Tse, C. Wolpert, W. Jung, A.J. Camm, C.-P. Lau, H. J.J. Wellens, et al.
Treatment of atrial fibrillation with an implantable atrial defibrillator -- long term results
Eur. Heart J., December 1, 2003; 24(23): 2083 - 2089.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
X. Zheng, M. E. Benser, G. P. Walcott, and R. E. Ideker
Right Atrial Septal Electrode for Reducing the Atrial Defibrillation Threshold
Circulation, August 28, 2001; 104(9): 1066 - 1070.
[Abstract] [Full Text] [PDF]


Home page
EuropaceHome page
G. Gasparini, A. Bonso, S. Themistoclakis, F. Giada, and A. Raviele
Low-energy internal cardioversion in patients with long-lasting atrial fibrillation refractory to external electrical cardioversion: results and long-term follow-up
Europace, January 1, 2001; 3(2): 90 - 95.
[Abstract] [PDF]


Home page
CirculationHome page
X. Zheng, M. E. Benser, G. P. Walcott, S. D. Girouard, D. L. Rollins, W. M. Smith, and R. E. Ideker
Reduction of Atrial Defibrillation Threshold With an Interatrial Septal Electrode
Circulation, November 21, 2000; 102(21): 2659 - 2664.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
D. Pfeiffer and B. Luderitz
The right atrial/transoesophagael approach for conversion of atrial fibrillation: a hybrid method for compromise?
Eur. Heart J., May 2, 2000; 21(10): 785 - 787.
[PDF]


Home page
CirculationHome page
R. A. S. Cooper, V. J. Plumb, A. E. Epstein, G. N. Kay, and R. E. Ideker
Marked Reduction in Internal Atrial Defibrillation Thresholds With Dual-Current Pathways and Sequential Shocks in Humans
Circulation, June 30, 1998; 97(25): 2527 - 2535.
[Abstract] [Full Text] [PDF]